Differences between revisions 8 and 9
Revision 8 as of 2020-12-06 18:39:25
Size: 932
Editor: HannahRoss
Comment:
Revision 9 as of 2020-12-06 18:47:47
Size: 1176
Editor: HannahRoss
Comment:
Deletions are marked like this. Additions are marked like this.
Line 11: Line 11:
 * After the participant has signed the informed consent sheet, have the participant brush through their hair with a disposable comb and clean off their face with a towelette (specifically on their nose and around their eyes, as electrodes will be placed there)  * After the participant has signed the informed consent sheet, have the participant brush through their hair with a disposable comb and clean off their face with a
 
towelette (specifically on their nose and around their eyes, as electrodes will be placed there)
Line 13: Line 14:
 * Using the tape measure, have the participant hold the start of it against their nasion and go over the top of their head until you reach the inion, then write down the measurement in cm.  * Using the tape measure, have the participant hold the start of it against their nasion and go over the top of their head until you reach the inion, and write the
 total number
down in cm
  *''Hannah has an image for this''
Line 15: Line 18:
[[attachment:nasion and inion.jpg]]  * Move the decimal point to the left of the total number, then measure that distance on the participant's forehead and mark it with a grease pen. This will be used as
 a reference for where the front of the cap should be placed.

 *

COVID safety notes

  • the researcher's and the participant's safety should both be taken into consideration
  • researchers should always wear a mask while conducting studies
  • protocols will be explained to shorten the exposure between researchers and participants


Setting Up

  • After the participant has signed the informed consent sheet, have the participant brush through their hair with a disposable comb and clean off their face with a towelette (specifically on their nose and around their eyes, as electrodes will be placed there)
  • Using the tape measure, have the participant hold the start of it against their nasion and go over the top of their head until you reach the inion, and write the total number down in cm
    • Hannah has an image for this

  • Move the decimal point to the left of the total number, then measure that distance on the participant's forehead and mark it with a grease pen. This will be used as a reference for where the front of the cap should be placed.


EEG Data Collection Checklist


"Standard" Processing Steps